A gauge is a small steel object that spends its life being separated from its paperwork. It is taken out of the box, used at a bench, set down next to two other gauges of nearly the same size, and put back — often into the wrong pocket. The certificate stays in a drawer. Whatever identifies the tool has to be on the tool.

What the marking has to answer

Three questions come up every time a gauge is picked up, and all three have to be answerable without opening a file:

QuestionMarking that answers itWhat goes wrong without it
What nominal size is this?nominal diameter and tolerance zoneadjacent sizes get mixed
Is it the go or the not-go?"GO" / "NO GO" plus the limit it representsparts pass that should fail
Which way does it wear?wear allowance direction on the go sidereplacement decided by eye

The third question is the one most often left unanswered. A go plug wears smaller and a no-go plug wears smaller too, but only one of them has an allowance to absorb it. Stamping the allowed wear direction — or simply "WEAR LIMIT" with the shop-floor dimension — turns a judgement into a reading.

Why ink does not survive

Marker pen is the default answer and the worst one. A gauge is handled with oily hands, wiped with solvent, and dropped into a case that rubs against it. Ink on a polished cylindrical surface fails in three ways:

It rubs off in weeks. A marker line on a 10 mm shaft, handled fifty times a day, is gone inside a month. The tool is then unmarked and nobody notices, because the box still says the right thing.

It transfers. Ink from one gauge marks the next one in the same pocket, so two tools end up claiming the same size.

It changes the measurement. On a small plug, a layer of ink a few micrometres thick sits exactly on the surface being measured. For a 0.5 mm pin it is irrelevant; for a go plug at its wear limit it is not.

What actually works: engraving on a non-working surface

The marking has to be permanent and it has to be away from the measuring surface. On a plug gauge the handle or the back face of the body is the right place; on a threaded gauge the end face; on a thin pin, the shank above the working length.

Laser marking is the current default for hardened steel and leaves a legible 0.1 mm deep mark without raising a burr. Electro-chemical etching works on the same surfaces and is cheaper for small batches. Stamping is acceptable only on a non-critical face, because it displaces metal and can bow a thin body.

What to avoid: engraving on the flank of a thread, on the measuring cylinder, or anywhere within one diameter of a working edge. A burr raised 5 µm from a stamping mark is enough to change a verdict on a marginal part.

Keeping the marking and the record in step

A marking that says one thing and a certificate that says another is worse than no marking, because it creates false confidence. Two habits keep them aligned:

Mark the certificate number, not just the size. A serial or asset number on the tool lets anyone trace the calibration record in seconds. Size alone cannot be traced once two gauges of the same size exist — which they always do.

Re-mark after any regrind or replacement. A reground go plug has a new dimension and usually a new wear allowance position. Leaving the old marking in place is how a tool ends up measuring to the wrong limit.

The practical test of a marking system: hand a gauge to someone who has never seen it and ask what it measures, whether it is go or not-go, and when it was last checked. If the answers take longer than thirty seconds, the marking is not doing its job.