Ask why a gauge is recalibrated every twelve months and the honest answer is usually that the last auditor did not object. The interval is a number that can be derived, and deriving it takes three quantities that a production engineer already has: insertions per year, the size of the tolerance band, and how much of that band the gauge is allowed to eat.
The point of the exercise is not paperwork. It is to know which gauges in the drawer are close to their limit before they start passing bad parts.
| Quantity | Typical value | How to get it |
| Product tolerance on the feature | 0.05 mm to 0.10 mm | From the part drawing |
| Gauge making tolerance | A tenth of that, often capped at 0.005 mm | From the gauge drawing |
| Wear allowance | Half the gauge tolerance, not more | A policy decision, write it down |
| Insertions per gauge per year | Thousands in production, tens in a lab | Count them, do not estimate |
| Wear per 1,000 insertions on hardened steel | Sub-micrometre to a few micrometres | Measure, then extrapolate |
| Interval implied by the budget | Often 3 to 12 months | Budget divided by wear rate |
With a 0.005 mm gauge tolerance and a 0.0025 mm wear allowance, a gauge that loses 1 µm per thousand insertions has a budget of 2,500 insertions, not twelve months. In a plant running 300 insertions a day that is eight working days, and the annual interval was never defensible.
Wear is not uniform. A plug gauge loses most of its material at the entry chamfer and along one line, because the part is inserted from one side. A thread gauge loses material on the flanks near the start thread. A flat gauge loses material at the edges where the part is dragged across it.
That means a single diameter measurement at mid-length can miss the wear entirely. Measure at the entry, at mid-length and at the tip, in two planes, and record the worst of the six readings.
Attach the interval to the gauge, not to a spreadsheet nobody opens: a tag with the last check date, the insertions counted and the next due count. Count insertions with a simple stroke counter on the fixture, which costs less than one hour of a metrologist and removes the guesswork entirely.
For laboratories with a small gauge set, the practical compromise is an annual check plus a check after any drop, any repair and any change of operator. A gauge set kept in a fitted case with individual slots survives far longer than the same gauges in a drawer, and the site index lists the setting rods and masters that make an in-house check possible.
Standards referenced: ISO 9001; ISO/IEC 17025.