A limit gauge is a wear part that has been given a certificate. That is the whole design brief. It has to hold a size to a few micrometres while being dragged across parts thousands of times, and the two properties that decide whether it can are hardness and surface finish.
Both are routinely left out of purchase specifications, because both are invisible on arrival and both only show up as a drift that nobody attributes to the gauge.
| Property | Typical specification | Consequence if too low |
| Hardness | 58 HRC to 62 HRC, through-hardened | Dings and burnishes; size drifts within a few hundred parts |
| Surface roughness | Ra 0.2 µm or better on the working surfaces | Rough peaks act as extra size; the gauge reads tight |
| Material | Hardened tool steel or hardened stainless | Aluminium and mild steel cannot hold a limit |
| Edge break | 0.1 mm to 0.2 mm, controlled | A sharp edge scrapes the part and wears itself |
| Flatness on a flat gauge | Micrometre order over the working face | A bowed gauge passes on one side |
58 HRC is not a magic number; it is the point where hardened steel stops deforming plastically under the contact pressures a gauge sees. Below about 50 HRC a gauge starts to burnish: the high points of the surface flow instead of wearing away, and the size moves without any visible damage.
A turned or ground surface with Ra 1.6 µm has peaks of roughly 5 µm above the mean line. Those peaks touch the part first. On a go gauge, that means the gauge measures the peaks, not the nominal surface, so it enters a hole that is genuinely 3 µm to 5 µm too small. On a not-go gauge the opposite happens and it refuses parts that are correct.
This is why a gauge specification that says only "hardened and ground" is not a specification. Ground can mean Ra 0.8 or Ra 0.1 depending on the wheel and the feed, and the difference is bigger than the gauge tolerance.
A rapid-prototyped gauge is fine to check that a fixture fits. It is not a gauge, and it should not carry a pass sticker.
Material and hardness with the test method, roughness with the parameter and the cut-off, working-surface finish, edge break, and the gauge drawing revision. Add one line about marking: a gauge without its sheet number and its own serial cannot be traced when it starts to drift, and a drawer of unmarked gauges is a drawer of unknown sizes.
For a laboratory that buys in small quantities, the certificate matters as much as the steel. A hardened go no go gauge supplied with both limit dimensions and a hardness reading can be put into service the day it arrives; one supplied with a nominal size only has to be measured before use. The site index groups the gauges by the standard they serve.
Standards referenced: ISO 6507-1; ISO 4287.