Home   |   Technical Articles

Technical Articles

When a Go/No-Go Gauge Should Be Pulled from Service

2026-11-13

A limit gauge is the least complicated tool in the inspection room, which is exactly why it gets ignored. There is no display to calibrate, no battery to change, and no reading to write down. The gauge either enters the hole or it does not. After a few thousand parts, though, "it still goes in" stops meaning what it used to mean.

The GO side wears, the NOT GO side does not

Under the Taylor principle, the GO member checks the maximum material size and has to pass through the whole length of the feature, so it rubs against the workpiece on every single check. The NOT GO member only has to be tried, and on a conforming part it never enters at all. In a high-volume line the GO end of a plug gauge can lose several micrometres a year while the NOT GO end is still within a micron of its original size.

That asymmetry matters. A worn GO plug is slightly smaller than it should be, so it will accept parts that are undersize. Nothing looks wrong: the gauge still slides in, the part still passes, and the error only shows up later when the mating component will not assemble. This is the most expensive kind of gauging error because it is systematic and silent.

Where the wear limit actually sits

Most shops work to a wear allowance of roughly 10% of the workpiece tolerance on the GO member, with a hard rejection line at the point where the GO size reaches the maximum material limit. Some national standards put the new-gauge manufacturing tolerance inside the workpiece tolerance zone and add a separate wear band; the numbers differ, but the logic is the same. Once the wear band is used up, the gauge is scrap, not "still usable for internal checks".

What to checkTypical trigger
GO member diameterWear allowance consumed (often ~10% of part tolerance)
NOT GO memberAny measurable growth in use, or visible edge rounding
Surface finish of the gauging facePitting, scoring, or a bright polished band
Handle and threaded jointAny play between members and holder

Check the GO and NOT GO members separately. A single measurement of "the gauge" tells you very little, and measuring the handle end is pointless.

Set the interval from usage, not from the calendar alone

A twelve-month cycle is a reasonable starting point for gauges used a few times a day on clean steel or aluminium parts. Change the interval when the conditions change:

  • Castings, sintered parts, or anything with residual sand or scale: shorten to three or six months. Abrasive surfaces eat carbide slowly but eat hardened steel fast.
  • Gauges used on more than one shift, or shared between lines: shorten. Frequency is per use, not per month.
  • Gauges kept as reference masters and used once a quarter: a two-year cycle is defensible if the storage is dry and the master is never used on the floor.
  • Any gauge that was dropped, jammed, or forced: check immediately, regardless of the date on the label.

Keep a simple log with the measured GO diameter and the date. Three data points in a row tell you the wear rate, and the wear rate tells you the interval far better than a rule of thumb. If the first six months cost 4 µm and the allowance is 10 µm, you already know this gauge will not survive the year.

Temperature and handling cause more false readings than wear

Limit gauges are calibrated at 20 °C. A steel plug held in a warm hand for a minute grows enough to matter at IT6 and IT7 tolerances. On a summer afternoon, parts straight off a grinder can be 8 to 10 degrees above ambient. Let both gauge and part soak on the same surface, use a glove or the insulated handle, and never measure a part that is still warm from machining.

Forcing is the other classic mistake. A GO gauge should enter under its own weight or a light, steady push. If it needs a twist or a tap, something is wrong with the part, the alignment, or the gauge itself. Forcing a tapered entry also polishes the leading edge, which is precisely where the wear allowance gets consumed first.

A short rule for the floor

Label every limit gauge with its identity, its last check date, and its measured GO size. Quarantine anything with an expired label rather than leaving it in the drawer "just in case". And when a gauge finally reaches its wear limit, destroy it or mark it unmistakably as a training piece. A worn-out GO gauge in a drawer has a way of finding its way back onto the bench on a busy shift.

No next
Scan the qr codeClose
the qr code