The comparative tracking index (CTI) is quoted on every datasheet and reproduced in every insulation coordination calculation, yet it is one of the easiest tests to run inconsistently. IEC 60112 fixes the apparatus and the procedure precisely; the variation comes from how carefully the operator holds those conditions for the full 50 drops.
Two platinum electrodes rest on the surface of the specimen under a defined load. A contaminant solution is dropped between them at a fixed interval while an AC voltage is applied. The test continues for 50 drops or until tracking occurs. The voltage at which tracking is avoided at 50 drops, confirmed by a second specimen, gives the CTI.
| Electrode load | 1.0 N per electrode. Check with a balance at the electrode tip, not at the lever. |
| Contaminant | Solution A: 0.1 % ammonium chloride in deionised water. Concentration drift from evaporation raises conductivity and lowers CTI. |
| Drop interval | 30 s, with a tolerance that most timers meet; hand timing does not. |
| Drop size and height | Fixed by the dosing syringe and the drop height; a partially blocked needle changes both. |
| Electrode condition | Platinum, cleaned, with the specified chisel edge. Residue from the previous specimen is the single biggest cause of early tracking. |
Tracking is not only a visible carbon path. The standard treats any of the following as failure: a current of 0.5 A or more flowing for 2 s, persistent flaming, or the specimen burning away between the electrodes. Because the trip is current-based, the series resistor and the trip setting have to be checked before the test, not after a suspicious result.
Starting too high wastes specimens; starting too low wastes time. A practical sequence is to begin near the expected class value, then step in 25 V increments. The CTI is the highest voltage at which 50 drops are survived on two specimens, with the second specimen confirming the first. Report the value and the test conditions together: a CTI of 600 measured with a diluted solution is not a CTI of 600.
Insulation coordination uses CTI to assign a material group: group I at 600 and above, group II at 400 to 599, group IIIa at 250 to 399, and IIIb below 250 in the common scheme. The group feeds directly into creepage distance selection, so an optimistic CTI shifts the whole design in the unsafe direction. Two points are worth remembering: