2026-11-16
Ask a machinist what size a 10 mm go plug gauge is and the answer is usually "10 mm, minus a bit". The "minus a bit" is the entire subject of this article. A go gauge is deliberately made to the low limit of the feature it checks, not to the nominal size, and the reason is not manufacturing convenience — it is the only way the inspection result means anything.
A limit gauge answers one question: is the feature inside its tolerance band? The go gauge represents the maximum material condition — the largest shaft or the smallest hole that is still acceptable. If the go gauge enters, the feature has not exceeded the material limit. The no-go gauge represents the minimum material condition; if it enters, the feature has gone too far the other way.
For a 10 mm shaft with a tolerance of 9.96 to 10.00 mm, the go gauge is made at 10.00 mm and the no-go at 9.96 mm. For a 10 mm hole with a tolerance of 10.00 to 10.04 mm, the go gauge is 10.00 mm and the no-go is 10.04 mm. In both cases the go gauge sits at the limit that guarantees assembly.
Three reasons, and they are not equally obvious:
ISO 1938 does not simply put the gauge on the limit line. It splits the space into a manufacturing tolerance for the gauge (T) and a wear allowance (Z), positioned inside the workpiece tolerance band. The practical consequence is a table worth keeping on the wall:
| Zone | What it covers | Practical effect |
| T | Gauge manufacturing tolerance | A new go gauge may be anywhere within T and is still acceptable |
| Z | Wear allowance | Extra material that may be worn away before the gauge must be replaced |
| Workpiece band | The tolerance the part is allowed | T and Z together are a small fraction of it, typically around 10 percent each |
The 10 percent figure is the one worth remembering. Gauge tolerance and wear allowance are each a modest slice of the part tolerance, which is why a gauge room reading of 10.001 mm on a go plug for a 10.00 mm limit is not automatically a scrap gauge. It is within T, and it is inside the allowance.
The withdrawal criterion is not "when it looks worn". It is when the gauge has worn past the wear limit, which is the maximum material limit plus Z for a plug checking a hole, or minus Z for a gauge checking a shaft. Because the direction is known, a single measurement decides it:
A worn go plug accepts every part the new gauge accepted plus a band of parts that are outside tolerance. The inspection produces the same answer, with the same confidence, for a different population of parts. Nothing on the shop floor changes until a mating part fails to assemble, and by then the batches in between are already through.
This is the argument for a gauging interval rather than a gauging policy. A go gauge used on abrasive parts can move several micrometres in a month; the same gauge on clean brass may hold its size for a year. Usage count is a better driver than calendar time, and the record should say which was used.
The plug and socket gauge range lists go and no-go gauges with their limit dimensions; the catalogue home page has the matching setting masters and wear check accessories.