Ask a machinist what size a 10 mm go plug gauge is and the answer is usually "10 mm, minus a bit". The "minus a bit" is the entire subject of this article. A go gauge is deliberately made to the low limit of the feature it checks, not to the nominal size, and the reason is not manufacturing convenience — it is the only way the inspection result means anything.

What a go gauge is for

A limit gauge answers one question: is the feature inside its tolerance band? The go gauge represents the maximum material condition — the largest shaft or the smallest hole that is still acceptable. If the go gauge enters, the feature has not exceeded the material limit. The no-go gauge represents the minimum material condition; if it enters, the feature has gone too far the other way.

For a 10 mm shaft with a tolerance of 9.96 to 10.00 mm, the go gauge is made at 10.00 mm and the no-go at 9.96 mm. For a 10 mm hole with a tolerance of 10.00 to 10.04 mm, the go gauge is 10.00 mm and the no-go is 10.04 mm. In both cases the go gauge sits at the limit that guarantees assembly.

Why the go gauge sits at the limit and not at nominal

Three reasons, and they are not equally obvious:

  • Assembly is the promise. If a part passes inspection it must fit its mating part. Only the maximum material limit carries that guarantee, so the go gauge must be at that limit.
  • Wear is one-directional. A go plug gauge wears smaller with use. Starting at the maximum material limit means wear moves it into the part it is checking, which would eventually accept bad parts — so a wear allowance is subtracted at manufacture to buy time.
  • The no-go gauge wears the other way. A no-go plug wears smaller too, which makes it less likely to enter and therefore more likely to reject good parts. The two gauges have opposite failure directions, and the tolerance zones are placed accordingly.

The three zones: T, Z and the workpiece tolerance

ISO 1938 does not simply put the gauge on the limit line. It splits the space into a manufacturing tolerance for the gauge (T) and a wear allowance (Z), positioned inside the workpiece tolerance band. The practical consequence is a table worth keeping on the wall:

ZoneWhat it coversPractical effect
TGauge manufacturing toleranceA new go gauge may be anywhere within T and is still acceptable
ZWear allowanceExtra material that may be worn away before the gauge must be replaced
Workpiece bandThe tolerance the part is allowedT and Z together are a small fraction of it, typically around 10 percent each

The 10 percent figure is the one worth remembering. Gauge tolerance and wear allowance are each a modest slice of the part tolerance, which is why a gauge room reading of 10.001 mm on a go plug for a 10.00 mm limit is not automatically a scrap gauge. It is within T, and it is inside the allowance.

When a go gauge must leave service

The withdrawal criterion is not "when it looks worn". It is when the gauge has worn past the wear limit, which is the maximum material limit plus Z for a plug checking a hole, or minus Z for a gauge checking a shaft. Because the direction is known, a single measurement decides it:

  1. Measure the go gauge at the wear zone — the part of the gauge that enters first, which is the front 20 to 30 percent of its length.
  2. Compare against the documented wear limit for that gauge size, not against nominal.
  3. If past the limit, withdraw. Re-cutting or re-lapping a worn go gauge changes the very dimension that gives the inspection its meaning, and a reworked gauge must be re-certified against the limit, not merely measured.

Why "it still fits" is not evidence

A worn go plug accepts every part the new gauge accepted plus a band of parts that are outside tolerance. The inspection produces the same answer, with the same confidence, for a different population of parts. Nothing on the shop floor changes until a mating part fails to assemble, and by then the batches in between are already through.

This is the argument for a gauging interval rather than a gauging policy. A go gauge used on abrasive parts can move several micrometres in a month; the same gauge on clean brass may hold its size for a year. Usage count is a better driver than calendar time, and the record should say which was used.

A short gauging discipline

  • Mark the gauge with its nominal size, limit and wear limit, not just its size.
  • Measure the wear zone, not the middle of the gauge.
  • Keep the setting master in the same room as the gauge; a 5 K difference across a 10 mm steel gauge is worth roughly 0.6 micrometres, which is not negligible on a fine tolerance.
  • Record the measurement, the date and the usage count together, so the interval can be set from evidence later.

The plug and socket gauge range lists go and no-go gauges with their limit dimensions; the catalogue home page has the matching setting masters and wear check accessories.